Model | S-200-5 | S-200-12 | S-200-15 | S-200-24 |
DC output voltage | 5V | 12V | 15V | 24V |
Output voltage rang(Note:2) | +/-2% | +/-1% | +/-1% | +/-1% |
Rated output current | 40A | 16.5A | 13.3A | 8.5A |
Output current range | 0-40A | 0-16.5A | 0-13.3A | 0-8.5A |
Wave and noise(Note:3) | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
Inlet stability(Note:4) | +/0.5% | +/0.5% | +/0.3% | +/0.2% |
Load stability(Note:5) | +/0.5% | +/0.5% | +/0.3% | +/0.3% |
DC output power | 200W | 200W | 200W | 200W |
Efficiency | 75% | 79.50% | 80% | 81.50% |
Adjustable range for DC voltage | 4.75-5.5V | 10.8-13.2V | 13.5-16.5V | 21.6-26.4V |
AC input voltage range | 180~264VAC47~63Hz; | |||
255~370VDC | ||||
Input current | 2.2A/230V | |||
AC inrush current | Cole-start current:36A/230V | |||
Leakage current | <0.5mA/240VAC | |||
Overload proctection | 105%~150%Type:pulsing hiccup shutdown Reset:auto | |||
recovery | ||||
Over-voltage proctection | 115%~135% | |||
High-temperature and protection | 115%~135% | |||
Temperature coefficient | +/-0.03%(0~50) | |||
Setup, rise,hold up time | 200ms,100ms,30ms | |||
Vibration | 10-500Hz,,2G10min,/cycle, periodfor 60min,Each axes | |||
Withstand voltage | Input and output interal:1.5KvAC,Input ad enclosure:1.5KvAC | |||
Output and enclosure:0.5KvAC |