| Customization: | Available |
|---|---|
| Output Type: | Single |
| Warranty: | 2 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Model | S-75-12 | S-75-15 | S-75-24 | S-75-48 |
| DC output voltage | 12V | 15V | 24V | 48V |
| Rated output current | 6A | 5.0A | 3A | 1.5A |
| Output current range | 0-6A | 0-5A | 0-3A | 0-1.5A |
| Wave and noise | 75mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
| Inlet stability | 0.50% | 0.50% | 0.50% | 0.50% |
| Load stability | 0.50% | 0.50% | 0.50% | 0.50% |
| Efficiency | 78% | 79% | 82% | 83% |
| Adjustable range for DC voltage | 10% | 10% | 10% | 10% |
| AC input voltage range: | 85~132VAC/170~264VAC selected by switch 47~63Hz;240~370VDC | |||
| AC inrush current: | Cold-start current 15A/115V 30A/230V | |||
| Overload protection: | 105%~150% Type:plusing hiccup shutdown Reset:auto recovery | |||
| Setup rise hold-up time: | 200ms,50ms,20ms | |||
| Withstand voltage:Input and output internal: | 1.5KvAC,Output and enclosure:0.5KvAC | |||