Multi-Functional Digital Panel Meter (JYS/JYK)

Warranty: 18 Months
Transport Package: Standard Exporting Carton
Specification: IEC 521
Trademark: JYINS
Origin: China
Customization:

Contact Supplier

Diamond Member Since 2008

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory

Basic Info.

Model NO.
JYS/JYK
HS Code
90303310
Production Capacity
80000pcs/month

Product Description

Multi-Functional Digital panel Meter (JYS/JYK)


Model: Multi-Function Power Instrument
Size: Panel dimension: 120× 120mm
Hole cutout dimension: 112× 112mm

Features: Adopt 4 rows LED to in charge of showing the commonly used electric consumption parameter by switching over. Under rated voltage reference frequency. And cosΦ =1.0 when the Load operating current is 0.001Im. The electric energy meter can start and continous to measure electric energy. When add 115% rated voltage, current loop will disconnect and have no current, and the instrument have no cumulatire electric energy and pulse output.

Technical specification parameter:
1. Input signal
Electric power network: Single-phase three-phase_three-wire three-phase_three wire
Input voltage
Rated value: AC 100V 220V 380V
Over-load: 1.2times rated value(continued), 2 times rated value (10S)
Watt-loss: 0.1VA(pieces/per)
Impedance: 200K
2. Auxiliary power: AC\DC 80-270 V
Watt-loss: 5VA


Specifications

1. CE certificate,
2. Experienced digital meter manufacture,
3. Products already exported to Singapore, USA, Peru, czech etc.
type Capability PD1999-2S4 PD1999-2S7 PD1999-2S9 PD1999-2SY
Importation
Measure
Show
 
network Three phase three wire, four ph four wire
voltage Specified value Inform when ordering
Over burden Persist:1.2%,moment:3/2s
Insulation resistive <VA(hour )
dissipation >400k
accurancy 0.5%(pns test ,accurancy class 0.5%)
current
 
Specified value Inform when ordering
Over burden Persist:1.2%,moment:3/2s
Insulation resistive <0.2VA
dissipation <20M
accurancy Pns testing (accurancy class 0.2Hz)
Frequency 40-60Hz,accurancy class 0.2Hz
Power Active/inactive see in the power ,accurancy class 0.5%
Electric energy measuring Plsitive and negative to calculate, accurancy class 0.5%
power
 
Working range AC,DC80-270V
Insulation resistive <5VA
Output
 
Digital interface Rs485,modbus-RTU treaty
The power pulse outputs(light insulation) 2 road electric power bein exportation ,light insulation
circumstance
 
Working circumstance 10-60 ºC 
Store enbironment -20-70 ºC
Security
 
Insulation Assistance power,input signal,output signal>1.5KV
weight Input,output,power supplu to outer shell>500 Ω
shape
 
Size(length,width ,height) 12081208130
weight 0.5Kg
 
Basic error of Ioading Power factor Power factor
0.01IE-0.05In 1 1.0
0.05Ie-Imax 1 0.5
0.02Ie-0.1In 0.5L/0.8C 1.0
0.1Ie-Imax 0.5L/0.8C 0.6

Send your message to this supplier

*From:
*To:
avatar Mr. Hoffer
*Message:

Enter between 20 to 4,000 characters.