50*50mm Analog Panel Ammeter (JY-50)

Installation: General Installation Meter
Display: Indicator
Usage: Meter for Industry and Home Use, Standard Electric Energy Meter, Multi-Functional Energy Meter, Maximum Demand Meter, Multi-rate Watt-hour Meters
Theory: Electronic Meter
Power Source: AC and DC
Measuring Range: X/5A, X/75mv, X/100V
Customization:

Contact Supplier

Diamond Member Since 2008

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory

Basic Info.

Model NO.
JY-50-Ammeter
Overall Dimension
50*50mm
Installation Dimension
40*40mm
Accuracy Class
1.5
Warranty
18 Months
Transport Package
Standard Exporting Packing or by Your Requirements
Specification
CE, RoHS
Trademark
Jyins
Origin
Yueqing, Zhejiang, China
Production Capacity
30, 000PCS/Year

Product Description

50*50mm analog panel ammeter (JY-50)

Uses and applications:
This series of meters is a direct imitation of power measurement display instruments, measuring DC current and voltage, AC current and voltage, frequency, power factor, phase sequence, power, synchronization instructions and other non-power measurements. It has been widely used in a variety of AC and DC transmission and distribution systems, power control panels and other electrical devices, in the industries of maritime shipping, rail transport, chemical flameproof, low voltage equipment, construction equipment, generators, machinery equipment, etc. Being able to make electrical measurement and non-power measurement, it is a high-end instrument applied in general environmental conditions.


Changes caused by the temperature:
Temperature range for reference: 23° C± 2° C, 13° C~23° C, and 23° C~33° C. The changes caused by the impact of temperature are not allowed to be out of the range of the level index ± 100%.
The installation:
Unless specified, the meter is usually installed in a vertical position. Other installation positions such as horizontal and inclined position can be installed according to the customer's requirements. The corresponding level of accuracy is only valid to the regulated installation position. The meter has two kinds of instruction angles: Right angle 90° And wide angle 250° .
Anti-vibration and anti-shock:
Anti-vibration: Complies with the standard of IEC60068-2-6; Frequency sweep range: 10-55-10Hz; Displacement amplitude: ± 0.15mm, ± 0.3mm; Frequency sweep cycles: 5 times; Sweep rate: 10ct/min; Maximum acceleration: 147m/s2(15g), 490m/s2(50g); RMS acceleration: 6.06g; Vibration time: 15 min. Anti mechanical shock: Complies with the standard of IEC60068-2-27.


Overload ammeter:
The conventional overload multiple times should be once or twice, and it can be customized to once, twice, 3 times and so on according to the user's requirements. Its function is to indicate the approximate transient overload current value, such as the start-up current when the motor stars, and so on.

Name

precision

normal specification

remark

AC ammeter

A

1.5

0.5-50A

can be directly connected

A

1.5

10/5A-800/5A
secondary current passed by current transformer
 

KA

1.5

1KA-10KA
secondary current passed by current transformer
 

AC voltmeter

V

1.5

10V-600V

can be directly connected

KV

1.5

1KV-35KV

100V secondary voltage passed by voltage transformer

DC ammeter

µA mA

2.5

50μA-500μA 1mA-500mA
can be directly connected
 

A

1.5

1A-15A

can be directly connected

A

1.5

15A-750A

 outer attached shunt 75mV 60mV 50mV

 

KA

1.5

1KA-3KA

outer attached shunt 75mV 60mV 50mV

 

DC voltmeter

V

1.5

3V-600V

can be directly connected

KV

1.5

1KV-3KV

outer attached resistance value

Send your message to this supplier