• Ce AC DC Panel Voltmeter (44L1-V)

Ce AC DC Panel Voltmeter (44L1-V)

Installation: General Installation Meter
Display: Indicator
Usage: Meter for Industry and Home Use, Standard Electric Energy Meter, Multi-Functional Energy Meter, Maximum Demand Meter, Multi-rate Watt-hour Meters
Theory: Electronic Meter
Power Source: AC and DC
DC Voltmeter Type: Electrostatic
Customization:

Contact Supplier

Diamond Member Since 2008

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory

Basic Info.

Model NO.
44L1-V
AC Voltmeter Type
Electric
Customized
Customized
Accuracy Class
1.5
Dimensions
100X80mm
Warranty
18 Months
OEM
Accepted
Transport Package
Carton
Specification
CE, Rohs
Trademark
jyins
Origin
Yueqing, Zhejiang, China
HS Code
85044019
Production Capacity
30000 PCS/Year

Product Description

CE ac dc Panel voltmeter (44L1-V)



Anti-vibration and anti-shock:

Anti-vibration: Complies with the standard of IEC60068-2-6; Frequency sweep range: 10-55-10Hz; Displacement amplitude: ± 0.15mm, ± 0.3mm; Frequency sweep cycles: 5 times; Sweep rate: 10ct/min; Maximum acceleration: 147m/s2(15g), 490m/s2(50g); RMS acceleration: 6.06g; Vibration time: 15 min. Anti mechanical shock: Complies with the standard of IEC60068-2-27.

Accuracy level:

The JY series of pointer meter: AC and DC voltmeter and ammeter to the level of 1.5 or 2.5, power meter to the level of 2.5, frequency meter to the level of 2.5, and power factor meter to the level of 2.5.

Overload ammeter:

The conventional overload multiple times should be once or twice, and it can be customized to once, twice, 3 times and so on according to the user's requirements. Its function is to indicate the approximate transient overload current value, such as the start-up current when the motor stars, and so on.

Extrinsic current shunt:

The voltage specifications of the extrinsic current shunt of DC ammeters are 150mV, 100mV, 75mV, 60mV and 50mV, which can be customized. The resistance of the conducting wire connecting the meter and the current shunt should within the range of 1525mΩ , to ensure the accuracy of the meter.

Name

precision

normal specification

remark

AC ammeter

A

1.5

0.5-50A

can be directly connected

A

1.5

10/5A-800/5A
secondary current passed by current transformer

KA

1.5

1KA-10KA
secondary current passed by current transformer

AC voltmeter

V

1.5

10V-600V

can be directly connected

KV

1.5

1KV-35KV

100V secondary voltage passed by voltage transformer

DC ammeter

µA mA

2.5

50μA-500μA 1mA-500mA
can be directly connected

A

1.5

1A-15A

can be directly connected

A

1.5

15A-750A

 outer attached shunt 75mV 60mV 50mV

KA

1.5

1KA-3KA

outer attached shunt 75mV 60mV 50mV

DC voltmeter

V

1.5

3V-600V

can be directly connected

KV

1.5

1KV-3KV

outer attached resistance value

Hz meter

Hz

2.5

45-55HZ 55-65HZ

36V.100V.127V.220V.380V

Power meter

KW.VAR

2.5

100V 380V 380-380KV

100V secondary voltage passed by voltage ; Secondary current passed by current transformer 5-10KA/5A

cosφ meter

cosφ

2.5

COSφ =0.5-1-0.5

100V/5A 220V/5A 380V/5A